Specialize In Electric Power Testing & Measurement

PMC200S Multifunctional Power Meter

Short Description:

1.Introduction

PMC200 Power Parameter Tester is widely used for energy management system, substation automation, distribution network automation, subdistrict power distribution, industrial automation, intelligent building, intelligent switchboard, switch cabinet, etc. It integrates the digitization, intellectualization and networking together, to replace the traditional equipments such as electric quantity transducer, numeric display instrument, data acquisition unit and recorder analyzer, etc. The multi-purpose lows the cost, and the simple wire connection simplifies the testing.


Product Detail

2.Functions and Features

Parameter Measurement Current
Voltage
Active/Reactive/Apparent Power
Power Factor
Frequency
Phase and Neutral Line
Wire Line and Phase Line
3 Phases and Single Phase
3 Phases and Single Phase
Energy Measurement Input/Output Active Energy
Input/Output Reactive Energy
Apparent Energy
1 Channel Pulse Output
1 Channel Pulse Output
Demand Statistics Current
Active/Reactive/Apparent Power
Current Value and Max.
Current Value and Max.
Maximum and Minimum Record the maximum, minimum and time of all measurement parameters
Restoration Rate 8 Restoration Stages; 4 Restoration Rate can be set
Power Quality Harmonic Distortion
31 times Harmonic Analysis
Current and Voltage
Current and Voltage
Communication Protocol MODBUS-RTU
Display STN LCD Display with big screen
Real-Time Clock
Year/Month/ Day/Hour/Minute/Second
Relay Output Module 2 Channels Relay Output
Programmable Alarm Setting of exceeding the limit
Remote Control  
Analog Input and Output Module 1 Channel Analog Input Measurement for 4-20mA DC
1 Channel Analog Input Measurement for 0-5V DC
2 Channels Analog Output for 4-20mA DC

 

3. Technical Parameter

Electrical characteristics

Measure Type

3P3W AC system, 3P4W AC system

Sampling rate

128 points per cycle

Data refresh rate

1S

Measure accuracy

Current

±0.2%FS

Voltage

±0.2%FS

Power

0.5S

Frequency

±0.001Hz

Active Energy

0.5S

Reactive Energy

1.0S

DC input(AI)

0.5% FS

DC output(AO)

0.5% FS

Input voltage characteristics

Measure Voltage

3 *220/380V(Directly input)

3 * 57.7/100V(PT secondary side)

Allowed overload capability

1.2 times / continuous

input resistance

300KΩ

Input current characteristics

Measure current

5A (CT Secondary side)Or 1A (CT Secondary side)

Allowed overload capability

1.2 times / continuous

input resistance

<0.1Ω

Binary input

Working voltage

12~24 VDC

input resistance

12KΩ

Isolation voltage

2KV

Relay Output

Node type

Mechanical contact

Node capability

220 VAC/5A、30 VDC/5A

4-20mA DC input measurement

Measure current

4-20mA

Allowed overload capability

1.2 times / continuous

input resistance

10Ω

Isolation voltage

2KV

0-5V DC input measurement

Measure Voltage

0-5V

Allowed overload capability

1.2 times / continuous

input resistance

12.5KΩ

Isolation voltage

2KV

4-20mA DC output

Open-circuit Voltage

15VDC

Load capability

≤600Ω

Isolation voltage

2KV

Power supply

AC

100~240 VAC/45-65Hz

DC

100~375 VDC

Power consumption

< 3W

Mechanical performance

Weight

0.5kg

IP Protection Level

Meter Panel IP52, Meter Host IP30

Dimension

Host

96 X 96 X 72 mm

Host+modules

96 X 96 X 120 mm

Working temperature

Display screen

-20~70℃

Meter

-25~70℃

storage temperature

Meter+display screen

-40~85℃

Relative humidity

5% – 90%RH, No condensation

EMC

Antistatic discharge interference

IEC 61000-4-2,Level 4

Anti-fast transient group pulse

IEC 61000-4-4,Level 4

Anti-surge

IEC 61000-4-5,Level 3

Resistance to power frequency magnetic field

IEC 61000-4-8,Level 3

Electrical insulation performance

Insulation resistance

GB/T13729,>50MΩ

Power frequency withstand voltage

GB/T13729,AC 2KV 50Hz /1min

Impulse voltage

GB/T13729,5KV,1.2/50us

 

PMC200S selection guide

Model specification:PMC200S-①-②-③-④-⑤
①Model code:
1 57.7/100V Rated measurement voltage,5A Rated measurement current。
2 57.7/100V Rated measurement voltage,1A Rated measurement current。
3 220/380V Rated measurement voltage,5A Rated measurement current。
4 220/380V Rated measurement voltage,1A Rated measurement current。
②Model code:
1 Power supply:85~264 VAC/45-65Hz,100~300 VDC 。
③Model code:
0 Without DI
4 4 Channels DI
④Model code:
0 Without relay output
1 Optional 1 channel relay output(RL1+、RL1- port)
2 Optional 2 channels relay output
⑤Model code:
ab ab is a 2 integer,a means AI01 port optional for AI/AO modules, b means AI02 port optional for AI/AO0 –none1  - 0-5V DC analog input measure(AI)2  - 4-20mA DC analog input measure(AI)3  - 4-20mA DC analog output(AO)

For example:  ab = 00,Means AI 01 port is not equipped with AI/AO module, AI02 port is not equipped with AI/AO module

ab = 12,Means AI01 port is equipped with 0-5V DC analog input measure AI/AO module, AI02 port is equipped with 4-20mA DC analog input measure AI/AO module

For example: Order model: PMC200S-3-1-4-2-12

Means PMC200S rated measure 220V/380V,5A, working power supply as 85-264VAC/45-65HZ,Optional with 4channels binary input(DI), 2 channels relay output; 1 channel 0-5V DC analog input measure(AI01 port),1 channel 4-20mA DC analog input measure(AI02 port)


  • Previous:
  • Next:

  • Write your message here and send it to us